zhouneng oil purifier company
|
Price: | 6000.0 USD |
Payment Terms: | T/T,L/C |
Place of Origin: | Chongqing, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
The plants filter impurities in oil efficiently and improve the quality of the product rapidly. It is used for treating the unqualified turbine oil, especially the seriously emulsified turbine oil. This products, which can rapidly and effectively remove the water, gas and impurities, aim at turbine oil's nature of high water content, easy emulsifiable and high impurity content, and make the oil recover the new oil's nature.
1. The automatic systems include the automatic system of advance infrared liquid-level, the automatic safeguard system of pressure, the automatic system of temperature constancy, and the automatic safeguard system of electricity.
2. With the trapezoidal, spiral, automatic back flushing system.
3. On-line oil purification can be carried out with turbine or water turbine automatically without any person.
4. Breaking emulsification thoroughly with high- molecule polymeric material.
5. Dewatering very effectively with once and for two steps dehydrating method. It can thoroughly clear away the liquid water, free water and 80% dissolved water.
6. With distinctive removing impurities technique filtering through double FH trapezoidal network and absorbing by high polymer material, this machine can make the ß3 equal or surpass 200 and make the cleanness lower grade 6(NAS1638).
7. With the advanced dielectric condensation devices.
Vacuum Turbine Oil Automation filter series adopt the advanced detaching theory of membrane, which works from moisture and emulsification to make emulsive lubricant clear. This machine breaks emulsification thoroughly, and the oil is very difficult to emulsify again after treatment. Its dehydration volume is large and it can absorb water on line. TYA series, which prevent lubrication system from damage, can effectively extend the lifetime of oil and protect turbine and other machinery.
Table 1 Technical Parameter
item | unit | TY-A-10 | TY-A-20 | TY-A-30 | TY-A-50 | TY-A-100 | TY-A-150 | TY-A-200 | ||
Flow rate | L/h | 600 | 1200 | 1800 | 3000 | 6000 | 9000 | 12000 | ||
Working vacuum degree | Mpa | 0.06 ~ 0.095 | ||||||||
Working pressure | Mpa | ≤0.3 | ||||||||
Running temperature | ℃ | 40 ~ 70(the temperature of turbo machine below 55℃) | ||||||||
Heating power | KW | 14 | 16 | 18 | 30 | 45 | 55 | 60 | ||
Total power | KW | 16 | 18 | 20 | 33 | 48 | 61 | 71 | ||
Inlet/outlet caliber | mm | φ25 | φ25 | φ25 | φ32 | φ42 | φ50 | φ50 | ||
size | L | mm | 1280 | 1350 | 1350 | 100 | 1500 | 1500 | 1600 | |
W | mm | 750 | 900 | 950 | 950 | 1000 | 1200 | 1350 | ||
H | mm | 1450 | 1450 | 1500 | 1600 | 1650 | 1800 | 1800 | ||
Weight | Kg | 320 | 400 | 420 | 450 | 750 | 800 | 900 |
Table2 Guarantee Data after Purification
Capability item | Data |
Moisture | ≤100PPM |
Break emulsification value | ≤15min (GB/F 7305) |
Clean degree | ≤6grade (NAS1638) |